60 Hz; 4 poles
Synchronous speed 1,800 rpm; 3,600 cycles/min; 2 pole pairs120 × 60 ÷ 4 = 1,800 rpm. A four-pole induction motor generally runs below this under load.
Enter a tool name or topic.
The rotating magnetic field of an AC motor has a synchronous speed set by the electrical frequency and the number of magnetic poles. The formula is rpm = 120 × frequency (Hz) ÷ poles. This tool also displays electrical cycles per minute and the number of pole pairs. It estimates field speed, not the actual loaded shaft rpm of an induction motor, which runs slightly slower because of slip.
Choose a task. Inputs stay in this page only.
120 × 60 ÷ 4 = 1,800 rpm. A four-pole induction motor generally runs below this under load.
120 × 50 ÷ 6 = 1,000 rpm. Changing pole count or frequency changes the rotating-field speed.
For an induction motor, slip is required to produce torque; the rotor commonly turns below the rotating field's synchronous speed.
Use the drive's actual output electrical frequency at the operating point, not necessarily the fixed utility mains frequency.
Using these sample input values gives the first labelled output above. Enter actual mechanical shaft output rather than electrical input power.
No. Replace the examples with your real values. Enter actual mechanical shaft output rather than electrical input power.